DUCT INSULATION SOLUTIONS

Typical residential HVAC systems lose 10-30% of heating and cooling energy when air ducts pass through unconditioned spaces. Insulating duct work serves to reduce this energy waste and lowers utility bills. Occupants are also more comfortable in houses with insulated ducts because heated or cooled air reaches the registers at higher or lower temperatures, respectively. This helps reduce builder costs associated with callbacks because homeowners are less likely to complain about heating or cooling problems.

 

REFLECTIVE-DOUBLE BUBBLE-REFLECTIVE

Thermo Reflect Duct Insulation is a double layer of poly-bubbles bonded to and sandwiched between two sheets of a unique Radiant Barrier metalicized reflective. Its unique construction is specially designed to help reduce condensation and radiant heat gain or loss in HVAC ducts... and no fire or flammability worries ... it passes NFPA Full Room Burn Test.

• 97% reflectivity
• Easy to install
• Fiber free and environmentally friendly
• Inhibits condensation, mold and fungi
• NFPA 286 Full Room Burn Test Approved
• Helps reduce heat loss through your duct surfaces
• Raises your cooling and heating efficiency
• Helps ensure better climate control and comfort
• R-6 with air-space, R-4.3 without air-space
• ASTM E84-Class 1/Class A fire rating approved also
• ASTM C411-Passed

Thermo Reflect

DESCRIPTION
FOIL/DBL BUBBLE/FOIL - SQ EDGE
FOIL/DBL BUBBLE/FOIL - SQ EDGE
FOIL/DBL BUBBLE/FOIL - SQ EDGE
FOIL/DBL BUBBLE/FOIL - SQ EDGE
FOIL/DBL BUBBLE/FOIL - SQ EDGE
FOIL/DBL BUBBLE/FOIL - SQ EDGE
FOIL/DBL BUBBLE/FOIL - SQ EDGE
Order #
T12290-24-050
T12290-36-050
T12290-48-050
T12290-48-100
T12290-48-125
T12290-60-100
T12290-60-125
SIZE
24" X 50'
36" X 50'
48" X 50'
48" X 100'
48" X 125'
60" X 100'
60" X 125'
ROLLS/BAG
2
1
1
1
1
1
1

 

INSTALLATION METHODS:

 

R-6.0 DUCT WRAP WITH FOAM SPACERS

1) Using the double-sided tape provided in the duct accessory kit, apply foam spacers to duct edges. Spacers do not need to be applied to the full length of the duct. Break the spacers and place them every 1 to 2 feet along the duct edges.
2) Wrap Duct Insulation around the duct over the spacers. Duct Insulation and duct surface to achieve R-6.0.
3) Tape all seams using UL181A FOIL tape.
4) Continue steps 1 to 3 until the entire duct is insulated.

 

R-5.5 LINEAR WRAP WITH SPACERS

1) Fasten reflective spacers around the duct with double coated tape every 2 to 3 feet.
This creates the air space (albeit small) needed to achieve an R-5.5.
2) Wrap insulation around the duct.
3) Seal all seams UL181A FOIL tape.

 

R-4.3 DUCT WRAP

1) Wrap Duct Insulation loosely around the duct to create a small air space between the insulation and duct surface.
2) Tape all seams using UL181A FOIL tape.
3) Continue steps 1 to 2 until the entire Duct is insulated.